| Contact Us for Quotation | Email:464560351@qq.com | Whatsapp: +8618620373879 |
Product Introduction
| The Fluke MDA 510 and MDA 550 Motor-Drive Analyzers save time and eliminate the hassle of setting up complex measurements, while simplifying the troubleshooting process for variable frequency drives. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, the MDA-500 Series has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence. The MDA-510 and MDA-550 are the ideal portable motor-drive analysis test tools and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems. |
Specification
| Measurement Function | |
|---|---|
| DC voltage (V dc) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 999 counts |
| Accuracy at 4 s to 10 us/div | ±(3 % + 6 counts) |
| AC voltage (V ac) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 999 counts |
| 50 Hz | ±(3 % + 10 counts) - 0.6 % |
| 60 Hz | ±(3 % + 10 counts) - 0.4 % |
| 60 Hz to 20 kHz | ±(4 % + 15 counts) |
| 20 kHz to 1 MHz | ±(6 % + 20 counts) |
| 1 MHz to 25 MHz | ±(10 % + 20 counts) |
| True-rms voltage (V ac+dc) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 1100 counts |
| DC to 60 Hz | ±(3 % + 10 counts) |
| 60 Hz to 20 kHz | ±(4 % + 15 counts) |
| 20 kHz to 1 MHz | ±(6 % + 20 counts) |
| 1 MHz to 25 MHz | ±(10 % + 20 counts) |
| PWM voltage (V pwm) | |
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |
| Accuracy | As Vac+dc for sinewave signals |
| Peak voltage (V peak) | |
| Modes | Max peak, min peak, or pk-to-pk |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 10 mV |
| Accuracy | |
| Max peak, min peak | ±0.2 division |
| Pk-to-pk | ±0.4 division |
| Full scale reading | 800 counts |
| General Specification | |
|---|---|
| Current (AMP) with current clamp | |
| Ranges | Same as V ac, Vac+dc or V peak |
| Scale Factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Accuracy | Same as Vac, Vac+dc or V peak (add current clamp accuracy) |
| Frequency (Hz) | |
| Range | 1.000 Hz to 500 MHz |
| Full scale reading | 999 counts |
| Accuracy | ±(0.5 % + 2 counts) |
| Voltage/Herz ratio (V/Hz) | |
| Purpose | To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives |
| Accuracy | % Vrms + % Hz |
| Voltage unbalance drive input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |
| Accuracy | Indicative percentage based on Vac+dc values |
| Voltage unbalance drive output and motor input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |
| Accuracy | Indicative percentage based on V PWM values |
| Current unbalance drive input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy | Indicative percentage based on Aac+dc values |
| Current unbalance drive output and motor input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy | Indicative percentage based on A ac values |
| Rise and fall time | |
| Readings | Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |
| Accuracy | As oscilloscope accuracy |
| Harmonics and spectrum | |
| Harmonics | DC to 51st |
| Spectrum ranges | 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |
| Shaft voltage | |
| Events / second | Indicative percentage based on rise and fall time (Impulse discharges) measurements |
| Report data capture | |
| Number of screens | Typical 50 screens can be saved in reports (depends on compression ratio) |
| Transfer to PC | Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool |
| Probe settings | |
| Voltage probe | 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |
| Current clamp | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Shaft voltage probe | 1:1, 10:1, 100:1 |
English