Xtester-Kanomax 2212 IAQ indoor air quality monitor capable of testing multiple parameters
INTRODUCTION
The Kanomax Indoor Air Quality Monitor – Model 2212 simplifies the labor involved and eliminates the need to purchase and learn multiple instruments. It simultaneously measures multiple parameters such as: CO, CO2, Temperature, and Relative Humidity. It is capable of calculating Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air. Calibration is easy and can be done by the user. The monitor can also check CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62. It is capable of examining a building’s IAQ conditions to optimize worker productivity and features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment. |
MAIN FEATURES
|
APPLICATIONS
|
TECHNICAL SPEICIFICATION
| Main Unit Specifications | ||
|---|---|---|
| Measurement Specifications | ||
| CO | Range | 0 to 500PPM |
| Accuracy | +/-3% of reading or +/-3PPM whichever is greater | |
| Resolution | 0.1PPM: 0-99PPM 1PPM: 100-500 PPM | |
| CO2 | Range | 0 to 5000PPM |
| Accuracy | +/-3% of reading or+/-50PPM whichever is greater | |
| Resolution | 1PPM | |
| Temperature | Range | – 4 to 140F (-20 to 60C) |
| Accuracy | +/- 1F (+/-0.5C) | |
| Resolution | 0.1F (0.1C ) | |
| Relative Humidity | Range | 2 to 98%RH |
| Accuracy | 2 to 80%RH: ±2%RH, 80 to 98%RH: ±3%RH | |
| Resolution | 0.1%RH | |
| General Specifications | ||
| Function | Normal Mode | Normal measuring (do not store and calculate the data.) relative humidity, CO, CO2, dew point, wet bulb temperature, absolute humidity and humidity ratio |
| Calculation Mode | Store the data, and calculate the maximum, minimum and average value. | |
| % OA Mode | Measure ventilation ratio (ask for ventilation ratio by calculating from temperature and CO2 value) | |
| Data Output Mode | Perform re-calculation of stored data and output of data to PC and Printer. | |
| Calibration Mode | Perform the calibration of CO and CO2. | |
| Output | Digital | RS232C |
| Analog (optional) | DC 0 to 1V | |
| Power Supply | Standard | 6x AA Batteries |
| Analog (optional) | DC 0 to 1V | |
| Dimensions | Unit | 3.4″ x 7.4″ x 1.6″ |
| Probe | Length: 12.5 inch / Diameter: 1.0 inch | |
| Weight | 1.2lbs (500g) | |
| What’s included | Meter, Operation manual, AA batteries, Probe stand, Probe, Calibration cap, Connection tube, Data processing software (DPS), RS-232C cable, Carrying case, NIST TRACEABLE CALIBRATION certificate. Optional Serial – USB adapter and AC adapter available. | |
English